• Built-in embedded A8 platform, totally against virus invasion, with high reliability.
• Operating system: Linux
• Digital multi-beam forming technology, precision delay-by-point dynamic receive focus, ultra-wideband imaging, adaptive image optimization, adaptive angiography, adaptive Doppler imaging.
• Ultra-wideband fully digital beam former: Dynamic Focus
• Gray-scale imaging unit
• M-mode imaging unit
• Visual adjustable dynamic range
• Gray-scale imaging unit, grayscale ≥256 levels, with excellent contrast resolution and the audience subtle and uniformity
Specification

• Gray scale:256 levels;
• Color scale:256 levels;
• Display:10.4’Flicker-inch high-resolution LCD dedicated medical color display  
• Power supply:100-240V~ 1.2-0.6A  Fre:50-60Hz;
• adapter output:DC12.8V 3.0A;
• power consumption:≤100VA
• main unit dimension:approx 256×150×326(mm,L×W×H);
• main unit N.W.:4.5Kg(without accessories);

Multimedia and peripheral equipment

• video printer;
• i-Station integrated workstations, to achieve store images, report generation and cloud printing capabilities;
• U disk (file management support, software upgrades, and one-key store function), DICOM interface, easy to doctor's data management, remote transmission;
• Dual TV output:PAL/NTSC。

Probes:
• 3.5MHz R60 convex probe (2.0/2.5/3.5/5.0MHz)
• 7.5MHz L40 linear probe (6.0/6.5/7.5/9.0MHz)
• 6.5MHz R20 micro-convex probe(5.0 / 6.5 /7.5 / 9.0 MHz)
• 6.5MHz linear rectal probe (4.5 / 5.5 / 6.5 / 7.5MHz)
 
Operating mode

1.    B、B/B、4B mode
2.    M、B/M mode
3.    CFM
4.    PDI
5.    PW
6.    THI

Operating System Setup

• Basic Setting:
• Interface language, time, date and date format, screen-savers time settings, key tone setting, standard setting, font brightness setting.
• Formula preset: gestational formula for cattle, dogs, horses, cats, goats, camels, sheep and pigs.
• Notes preset: disease, routine, abdominal, obstetric, cardiac, urology, superficial seven kinds, can be preset for each common noun, and can be added, modified and edited according to the actual requirements, very user-friendly
• Stored presets: Photo storage format selection: BMP, PNG format (image compression format).
• Password preset
 
Main functions

1.    System Preset;
2.    I-User-defined, to store the setting while he used the main unit to save time to set again.
3.    Probe switch;
4.    Mode switch;
5.    Magnification / Depth selection;
6.    Frequency switch;
7.    frame switch;
8.    ID;
9.    Compression curve
10.    IP;
11.    Focus switch;
12.    Up/down, left/right reverse;
13.    TGC, Gain & Dyn adjustment;
14.    iImage optimization imaging technology;
15.    color frequency、PRF、wall filter adjustment;;
16.    Deflection angle, sample volume, linear color deflection, velocity scale, baseline function can be adjusted;
17.    Adjustable harmonic;
18.    B mode normal measurement, M mode routine measurements, CFM mode routine measurements, PDI mode routine measurements, PW mode measurements; and abdominal measurement applications, obstetrics application measurement, measuring cardiac applications, measuring urinary system applications, superficial organ application measurement;
19.    sound power adjustable;
20.    puncture guiding function;
21.    Gravel location positioning function;
22.    Built-in disk storage 16G, mass storage images, reports, videos, permanent storage, (BMP format picture ≥ 10 thousands, PNG format images ≥100 thousands)
23.    image management function;
24.    Mass video storage and replay(Under B mode:380,under M mode: 4000)
25.    Body mark;
26.    Note input;
27.    Patient info input;
28.    Report generation;
29.    One key store;
30.    One key to get report;
31.    One key to transfer image to Network Printer to print the image;
32.    LCD brightness adjustable;
33.    Energy saving;
 
Image treatment

• Image pretreatment
Total gain:0~127 dB
TGC:8 stagesTGC
Power output:25%、50%、75%、100%
Digital channels:32
• Image treatment
IE:0~3
Frame correlation:0~3
IP:0~7
Compression curve:0~7
• Scanning parameters

B Mode:
1.    B sound output:25%、50%、75%、100%
2.    B Gain:0~127
3.    Depth:32~252 mm (35 scales)
4.    Dyn:30~100dB
5.    Frequency:4 scales
6.    Harmonic:2 scales

M Mode:
1.    M sound output:25%、50%、75%、100%
2.    M Gain:0~127dB
3.    Depth:32~252 mm (35 scales)
4.    M Dyn:27~100dB
5.    M Scanning speed:1~8 adjustable
6.    M sampling line Visual & adjustable
7.    M scanning mode::scrolling & scanning
8.    Frequency:4 scales
9.    Harmonic:2 scales

CFM Mode、PDI Mode:
1.    Output:25%、50%、75%、100%
2.    CFM Gain:0~127dB
3.    Color frequency:2 scales
4.    Max PRF:7.5kHz
5.    Min PRF:0.35kHz
6.    CFM wall filter:8步50-350Hz
7.    Sensitivity:6 kinds
8.    Color afterglow:4 kinds
9.    Color Threshold:6 kinds
10.    Color balance:16 steps
11.    Color Smoothing:3 steps
12.    artifact removal:2 steps
13.    Linear color deflection adjustable
14.    Image Optimization:12 scales

PW Mode:
1.    Sound outpt:25%、50%、75%、100%
2.    PW Gain:0~127dB
3.    PW Dyn:13 scales 0-120
4.    PW frequency:2 scales
5.    PW wall filter:8 steps 50-350Hz
6.    Noise Reduction:4 scales
7.    sample volume width:0.5-20mm
8.    angle correction
9.    basic line adjustment:7 steps
10.    Max PRF(speed):7.5kHz
11.    Min PRF(speed):0.35kHz
12.    speed ruler:8 steps
13.    Volume:adjustable
14.    Linear color deflection adjustable

Measurement & calculation

• Routine measurement: measurement software package & report for B mode、M mode、D mode
• OB software for Cattle, dogs, horses, cats, goats, camels, sheep and pigs;
• Software package for urological measurement & analysis
• Software package for superficial organs measurement & analysis
• Software package for cardio measurement & analysis

Reports

• OB, Cardio, Urological report

Marks

• 127 kinds body marks with arrow position
•  Note mark, text input;
• Arrow mark

Standard configuration

• Main unit  1PC
• 3.5MHz convex probe  1PC;
• 6.5MHz linear rectal probe or 7.5MHz linear probe or 6.5Mhz micro-convex probe
• Working station 1 set
• Net cable 1pc
 
Optional parts

• Foot switch
• trolley
• video printer(UP-897MD)
• Ethernet Switch

    TRANSDUTOR MICRO CONVEXO

    trans mc

    MULTIFREQUENCIAL DE
    5.0/6.5/7.5/9.0 MHz

    Este Transdutor é indicado para exames gerais em Pequenos e Médios Animais (Caninos, Felinos, Suinos, Caprinos, Ovinos, etc)

    TRANSDUTOR LINEAR DE ALTA

    trans la

    MULTIFREQUENCIAL DE
    6.0/6.5/7.5/9.0 MHz

    Este Transdutor é indicado para exames gerais em Pequenos e Médios Animais (Caninos, Felinos, Suinos, Caprinos, Ovinos, etc) e para exames de tensão e músculo em Equínos.

    TRANSDUTOR CONVEXO

    trans cx

    MULTIFREQUENCIAL DE
    2.0/2.5/3.5/5.0 MHz

    Este Transdutor é indicado para exames de reprodução em Pequenos e Médios Animais (Caninos, Felinos, Suinos, Caprinos, Ovinos, etc)

    TRANSDUTOR LINEAR RETAL

    trans lr

    MULTIFREQUENCIAL DE
    4.5/5.5/6.5/7.5 MHz

    Este Transdutor é indicado para exames de reprodução em Grandes e Médios Animais (Equinos, Bovinos, Caprinos, Ovinos, etc)

    TRANSDUTOR CONVEXO RETALtrans cr

    MULTIFREQUENCIAL DE
    2.0/2.5/4.0/5.0 MHz

    Este Transdutor é indicado para exames de reprodução em Grandes e Médios Animais (Equinos, Bovinos, Caprinos, Ovinos, etc)

  • 1
    • IMAGEM

      dcu12 img a

      VEIA HEPÁTICA

      IMAGEM

      dcu12 img b

      VESÍCULA BILIAR

      IMAGEM

      dcu12 img c

      ARTERIA COELIACA

  • 1
    • FOTO

      FOTO

      FOTO

      FOTO

      FOTO

      FOTO

  • 1
  • 2
  •  

    LANÇAMENTO(s)

      ULTRASSOM
      RKU10 VET
      ULTRA PORTÁTIL
      ULTRASSOM
      DVU60 VET (com óculos)
      ULTRA PORTÁTIL
      ULTRASSOM
      UT01 VET
      AVALIAÇÃO DE TOUCINHO
      ULTRASSOM
      DCU12 VET
      DOPPLER
      ULTRASSOM
      KX5600 VET
      ULTRA PORTÁTIL
      ULTRASSOM
      MSU2 VET
      ULTRA PORTÁTIL
      ULTRASSOM
      DCU10 VET
      DOPPLER
      RAIO-X
      DR MARS1417V
       
  • 1
  • Fale Conosco via Whats App